Ceiling Mounted Fire Alarm Devices
7 field selectable candela settings for wall and ceiling mount devices and rotary switches to select horn tone and volume settings.
Ceiling mounted fire alarm devices. Lay the foundation for reliable alarming and evacuation in your building with our extensive portfolio of addressable ceiling and wall mounted sounders voice sounders and beacons. 177 cd ceiling 177 cd ceiling 177 cd ceiling 177 cd ceiling. Visual notification appliances are fire alarm devices that provide visual notifi cation of a life safety system event. This is a continuation on the series of articles about the most important requirements in nfpa 72 national fire alarm code book.
Ceiling mounted fire strobes should not be more than 30 feet above the floor. Refer to the annex of nfpa 72 for exceptions to these guidelines a 18 5 4 3. Wall mounted fire strobes must be placed 80 to 96 inches above the floor and at least six inches from the ceiling in all non sleeping areas. A plan view of a ceiling mounted fire alarm notification device s coverage area shows that the coverage projects outward along the strobe s mounting surface at an equal distance on all sides creating the square coverage areas listed in nfpa 72.
System sensor is a global manufacturer of fire and life safety devices in smoke detection carbon monoxide detection and notification technology. If the ceilings are higher than 30 feet the strobes must be mounted on the wall. It should be obvious that if you follow this method of compliance you will either have an incorrect number of audible appliances or an incorrect number of visible appliances. The strobe is always located in the center of the coverage area.
Nfpa 72 chapter 5 initiating devices heat detectors. Alarm code 2007 edition an installation standard for fire alarm systems normally not adopted directly into law but referenced in a building code as the standard to be followed. Currently the nfpa 72 and ifc 2006 edition ansi 2003 have been harmonized. Except where an existing fire alarm system is upgraded or replaced or a new fire alarm system is installed the adaag goes on to define an alteration as a change to a building or facilitythat affects or could affect the.
See 18 5 4 1 and 18 5 4 2 and for ceiling mounted strobes no more than 30 ft. 3 3 applications for ceiling mounted strobes 38 3 4 corridors 42 3 5 sleeping areas 43 3 6 strobes in harsh and hazardous environments 45 3 7 summary 46 4. Compatible with 12 or 24 volt systems. To effectively guide people to safety in case of an emergency fire alarm devices in public and commercial buildings must be carefully matched to local requirements.